Dual Control/Supply Lighting Distribution Box
Use to control 2 groups of luminaires independently of each other (same circuit, separate control) or to control 2 individual circuits of luminaires (2 protective devices at the distribution board(s) - must be the same phase). Supplied ready for Dual Control applications and ideal for controlling luminaires adjacent to windows separately to those further away. Simply remove factory fitted links from wiring compartment terminals for Dual Supply applications. Ideal for Essential / Non-Essential applications in hospitals for example. Regardless of application, these Distribution Boxes support standard (on/off) or dimmable lighting control in emergency or non-emergency versions.Key Features
- Controls 2 groups of luminaires independently of each other.
- Controls 2 individual circuits of luminaires.
- Outlets rated 16A 230V. Total system rating 16A.
- Large capacity input terminals can accept 3 x 2.5mm², 2 x 4mm² or 1 x 6 mm² conductors.
- 7-pole – ideal for on/off or dimming control
- End outlet can be used as a spare, or to plug-in additional units.
- All units come with unique snap on/off single point fixing brackets.
Expanding a Dual Supply Distribution Box
If you want to add extra luminaires at any stage you just need to plug an Expansion Box into your Dual Supply Box to provide extra outlets. Extra outlets will be added to Supply Group B.
If you want to control an extra group of luminaires separately, share just power from your Dual Supply Box using a Supply Tap-off Box.
You can plug them in direct unit-to-unit, or via a lead.
Dual Control Wiring Diagrams – 1 supply, 2 Control
Using flex7 plug-in control devices c/w integral emergency luminaire test means only a permanent live, neutral and earth are required.
Note: Retain factory fitted link for Dual Control Applications.
Using flex7 plug-in control devices without integral emergency luminaire test means only a permanent live, emergency live, neutral and earth are required.
Note: Retain factory fitted link for Dual Control Applications.
Using more traditional hard-wired control and emergency luminaire test means only a permanent live, emergency live, neutral, earth and 2 x switch live are required.
Note: Retain factory fitted link for Dual Control Applications.
Incorporating alongside a centralised control system means a permanent live, neutral, earth and 2 x control pair (if desired) eg. DALI are required.
Note: Retain factory fitted link for Dual Control Applications.
Standard flex7 wiring configurations for all 10 terminals in a Dual Control Application.
Note: Retain factory fitted link for Dual Control Applications.
Dual Supply Wiring Diagrams – 2 Supply, 2 Control
Using flex7 plug-in control devices c/w integral emergency luminaire test means 2 x permanent live, 2 x neutral and 2 x earth are required.
Note. Although the 2 supplies have different protective devices, they must be the same phase.
Note: Remove factory fitted link for Dual Supply Applications.
Using flex7 plug-in control devices without integral emergency luminaire test means 2 x permanent live, 2 x emergency live, 2 x neutral and 2 x earth are required.
Note. Although the 2 supplies have different protective devices, they must be the same phase.
Note: Remove factory fitted link for Dual Supply Applications.
Using more traditional hard-wired control and emergency luminaire test means 2 x permanent live, 2 x emergency live, 2 x neutral and 2 x earth 2 x switch lives are required.
Note. Although the 2 supplies have different protective devices, they must be the same phase.
Note: Remove factory fitted link for Dual Supply Applications.
Incorporating alongside a centralised control system means 2 x permanent live, 2 x neutral and 2 x earth 2 x control pair (if desired) eg. DALI are required.
Note. Although the 2 supplies have different protective devices, they must be the same phase.
Note: Remove factory fitted link for Dual Supply Applications.
Standard flex7 wiring configuration for all 14 terminals in a Dual Supply Distribution Box.
Note: Although the 2 supplies will have different protective devices, they must be the same phase.
Note: Remove factory fitted link for Dual Supply Applications.
Ordering information for standard Dual Control/Supply Distribution Box – 50:50 Split Point
Description | Part numbers |
---|---|
2-way Dual Control/Supply Starter Distribution Box, Split 1/1 | FSU02DS1/1 |
4-way Dual Control/Supply Starter Distribution Box, Split 2/2 | FSU04DS2/2 |
6-way Dual Control/Supply Starter Distribution Box, Split 3/3 | FSU06DS3/3 |
8-way Dual Supply Starter Distribution Box, Split 4/4 | FSU08DS4/4 |
10-way Dual Control/Supply Starter Distribution Box, Split 5/5 | FSU10DS5/5 |
12-way Dual Control/Supply Starter Distribution Box, Split 6/6 | FSU12DS6/6 |
Ordering information for bespoke Dual Control/Supply Distribution Box – built to order
Description | Part numbers |
---|---|
4-way Dual Control/Supply Starter Distribution Box, Split 3/1 | FSU04DS3/1 |
6-way Dual Control/Supply Starter Distribution Box, Split 5/1 | FSU06DS5/1 |
6-way Dual Control/Supply Starter Distribution Box, Split 4/2 | FSU06DS4/2 |
8-way Dual Control/Supply Starter Distribution Box, Split 7/1 | FSU08DS7/1 |
8-way Dual Control/Supply Starter Distribution Box, Split 6/2 | FSU08DS6/2 |
8-way Dual Control/Supply Starter Distribution Box, Split 5/3 | FSU08DS5/3 |
10-way Dual Control/Supply Starter Distribution Box, Split 9/1 | FSU10DS9/1 |
10-way Dual Control/Supply Starter Distribution Box, Split 8/2 | FSU10DS8/2 |
10-way Dual Control/Supply Starter Distribution Box, Split 7/3 | FSU10DS7/3 |
10-way Dual Control/Supply Starter Distribution Box, Split 6/4 | FSU10DS6/4 |
12-way Dual Control/Supply Starter Distribution Box, Split 11/1 | FSU12DS11/1 |
12-way Dual Control/Supply Starter Distribution Box, Split 10/2 | FSU12DS10/2 |
12-way Dual Control/Supply Starter Distribution Box, Split 9/3 | FSU12DS9/3 |
12-way Dual Control/Supply Starter Distribution Box, Split 8/4 | FSU12DS8/4 |
12-way Dual Control/Supply Starter Distribution Box, Split 7/5 | FSU12DS7/5 |